The Aerostat XC provide excellent coverage to protect sensitive electronic components. It features inherently balanced to 0 +/- 5V, and no calibration work is required. The built-in patented emitter point cleaner minimize the work of emitter tip cleaning.
Power Required :
100VAC, 50/60Hz, 1.0A max.
Static Control Characteristic :
Ion Balance : 0 +/- 5V
Decay Time : 2 seconds (measured at 0.3m distance, from 1000V to 100V,
according to EOS/ESD 3.0 standard)
Effective Coverage : (W) 0.9 m x (D) 1.8 m
Air Flow Characteristic :
Air Flow : 1.5 - 2.0 m3 per min
Noise : 56db at min fan speed, 62 db at max fan speed. (measured at
0.6m distance)
Other Characteristic :
Ozone Generation : < 0.02 ppm (using DASIBI Ozone Monitor Model
1003 AH)
Size : (W) 391mm x (D) 219mm x (H) [with stand 188mm, without stand
115mm]
Weight : 8 kg
Specification are subjected to change without prior notice
(End of Page)